  • Dial Reading Viscometer - máy đo độ nhớt dạng kim

Dial Reading Viscometer

From 207,494,000VNĐ

In stock

Dial Reading Viscometer

AMETEK Brookfield’s original Dial Reading Viscometer has been the lab standard used around the world since 1934. Now offered with multi-speed electronic drive and ergonomically designed speed control knob for ease of use.  

Description

  • Dial Reading Viscometer is the lab standard used around the world.
  • The original Brookfield Dial Reading Viscometer has been the lab standard used around the world since 1934. Current units have been been improved with a multi-speed electronic drive and ergonomically designed speed control knob so selection of any one of the 10 pre-set speeds (8 speeds on LVT models) is quick and easy.
  • The direct-drive design results in extremely quiet operation and greater versatility while the universal power supply facilitates the use of worldwide power sources.

Features and Benefits  

  • Easy-to-Select Speeds 
  • Electronic Drive for quiet, reliable operation 
  • Analog display
    – Shows % Torque
    – Use Factor Finder to convert the reading to centipoise 
  • Simple-to-use, easy setup 
  • Accuracy: ±1.0% of range 
  • Repeatability: ±0.2% 

TORQUE EXPLANATIONS:

  • LV is for low viscosity materials and can measure the thinnest materials. Typical examples include inks, oils, and solvents.
  • RV is for medium viscosity materials than those measured with an LV torque. Typical examples include creams, food, and paints.
  • HA is for higher viscosity materials than those measured with an RV torque. Typical examples include gels, chocolate and epoxies.
  • HB is for even higher viscosity materials than those measured with an HA torque spring. Typical examples include asphalt, caulking compounds, and molasses.

SPECIFICATIONS

VISCOSITY RANGE cP(mPa·s) SPEEDS
MODEL Min. Max. RPM Number of Increments
LVT 1 † 2M .3-60 8
RVT 100 †† 8M .5-100 10
HAT 200 †† 16M .5-100 10
HBT 800 †† 64M .5-100 10

† 1 cP achieved with UL Adapter accessory. 15 cP on LV with standard spindles.
††Minimum viscosity is achieved with optional RV/HA/HB spindle.
M=1 million cP=Centipoise mPa·s=Millipascal·seconds

SPRING TORQUE

SPRING TORQUE
MODEL Dyne-cm Milli Newton-m
LVT 673.7 0.0673
RVT 7,187.0 0.7187
HAT 14,374.0 1.4374
HBT 57,496.0 5.7496

† 1 cP achieved with UL Adapter accessory.  15 cP on LV with standard spindles.
††Minimum viscosity is achieved with optional RV/HA/HB spindle.
B=1 Billion     M=1 million     cP=Centipoise     mPa·s=Millipascal·seconds

What’s Included

  • Instrument
  • 6 spindles (RV) or 4 spindles (LV)

ametek brookfield - bộ spindle LV

ametek brookfield - bộ spindle RV

  • Guard Leg *Not applicable to HA or HB torque models
  • Lab stand (Model G)
  • Carrying Case

Related Accessories

Additional information

Lựa chọn thang đo

HA, HB, LV, RV

Nhân viên hỗ trợ

Line 1
Line 2
Line 3
Line 4