membraPure Water Purification Systems | Aquinity² P35 / P70
Model: AQUINITY² P35 / P70
membraPure GmbH
membraPure Water Purification Systems Aquinity² P35/P70 versions have an independent tank from which RO water can be tapped (e.g. for glassware cleaning).
The water quality from this tank depends on the feed water quality; in general the RO holds back 98% of all ions. The tank can be installed at the side or above the system or even underneath the bench.
Tapping of ultrapure water is done with our flexible but also lockable dispenser as incorporated in all membraPure ultrapure water systems. Built-in TOC monitoring is also available with the Aquinity² P35/P70 versions.
membraPure Water Purification Systems Aquinity² P35/P70 is the perfect system for a medium-sized lab.
- Permeate rate: 10 l/h
- Resistivity: 18.2 MOhm x cm
- Reservoir: 35 l or 70 l
- Flow Rate UPW: 2 l/min
- TOC
< 10 ppb (Reagent)
< 3 ppb (Analytical with UV)
< 5 ppb (LifeScience with UV and UF) - Endotoxins: < 0.001 EU/ml endotoxins (LifeScience)
Module | Reagent | Analytical | LifeScience | Analytical TI | LifeScience TI |
---|---|---|---|---|---|
Article number | 114-0060 | 114-0061 | 114-0062 | 114-0066 | 114-0067 |
Water Quality | |||||
Application: | |||||
AAS | yes | yes | yes | yes | yes |
ICP | yes | yes | yes | yes | yes |
Low Level Applications | yes | yes | yes | yes | yes |
HPLC | no | yes | yes | yes | yes |
CE | no | yes | yes | yes | yes |
ICP-MS | no | yes | yes | yes | yes |
Cell Culture | no | no | yes | no | yes |
Gentics | no | no | yes | no | yes |
Modules: | |||||
UV-Reactor | no | yes | yes | yes | yes |
Ultrafiltration (UF) | no | no | yes | no | yes |
TOC-Display | no | no | no | yes | yes |
Ultra pure water cartridge | 190-0088 | 190-0088 | 190-0087 | 190-0088 | 190-0087 |
Filter Sterile | 190-0013 | 190-0013 | 190-0013 | 190-0013 | 190-0013 |
Installation-Kit | N/A | N/A | N/A | N/A | N/A |
Options: | |||||
Microsiemens feed water check | N/A | N/A | N/A | N/A | N/A |
memTAP Dispenser | 180-0074 | 180-0074 | 180-0074 | 180-0074 | 180-0074 |
Feed water requirements | |||||
Water quality | tap water less than 1400μS/cm | tap water less than 1400μS/cm | tap water less than 1400μS/cm | tap water less than 1400μS/cm | tap water less than 1400μS/cm |
Temperature | <20°C | <20°C | <20°C | <20°C | <20°C |
Ultra pure Water (Type I) | |||||
Resistivity At 25°C | 18,2 MΩ | 18,2 MΩ | 18,2 MΩ | 18,2 MΩ | 18,2 MΩ |
Conductivity At 25°C | 0,055μS | 0,055μS | 0,055μS | 0,055μS | 0,055μS |
Flow Rate | 2 l/min | 2 l/min | 2 l/min | 2 l/min | 2 l/min |
TOC Level | < 10 ppb | < 3 ppb | < 5 ppb | < 3 ppb | < 5 ppb |
Endotoxin (Pyrogens) | N/A | N/A | 0,001 EU/ml | N/A | 0,001 EU/ml |
Particulate | < 1/ml (>0.22μm) | < 1/ml (>0.22μm) | < 1/ml (>0.22μm) | < 1/ml (>0.22μm) | < 1/ml (>0.22μm) |
Bacteria | ≤ 1 cfu/10ml | ≤ 1 cfu/10ml | ≤ 1 cfu/10ml | ≤ 1 cfu/10ml | ≤ 1 cfu/10ml |
DNAse/RNAse | N/A | N/A | < 1 pg/ml/< 5 pg/ml | N/A | < 1 pg/ml/< 5 pg/ml |
High purified Water from RO or EDI | |||||
Conductivity At 25°C | approx 10μS | approx 10μS | approx 10μS | approx 10μS | approx 10μS |
TOC | < 50 ppb | < 50 ppb | < 50 ppb | < 50 ppb | < 50 ppb |
Production Rate | 10l/h | 10l/h | 10l/h | 10l/h | 10l/h |
Ionic Rejection | 98% | 98% | 98% | 98% | 98% |
Electrical Requirements | |||||
Electrical Voltage | 100-230 V | 100-230 V | 100-230 V | 100-230 V | 100-230 V |
Packing Information | |||||
Net Weight: | 25kg with empty tank | 25kg with empty tank | 25kg with empty tank | 25kg with empty tank | 25kg with empty tank |
Water tank | 70l | 70l | 70l | 70l | 70l |
External Dimensions (WxDxH in mm) | |||||
Main units | 504 x 680 x 535 | 504 x 680 x 535 | 504 x 680 x 535 | 504 x 680 x 535 | 504 x 680 x 535 |