Close

Sản phẩm

  • Dissolved qxygen controller alpha DO 2000

Dissolved oxygen controller Alpha DO 2000

From

With a wide measuring range of 0 to 20 ppm or 0 to 200 % saturation, Dissolved oxygen controller alpha DO 2000 Eutech – Thermo Scientific is ideal for use in a variety of applications, ranging from water treatment and monitoring to pharmaceutical and food processing. Meter comes in both Galvanic and Amperometric versions.

In stock

DISSOLVED OXYGEN CONTROLLER ALPHA DO 2000

EUTECH – THERMO SCIENTIFIC

Product Features

Dissolved Oxygen Controller Alpha DO 2000

Dissolved Oxygen Controller Alpha DO 2000

With a wide measuring range of 0 to 20 ppm or 0 to 200 % saturation, Dissolved oxygen controller alpha DO 2000 Eutech – Thermo Scientific is ideal for use in a variety of applications, ranging from water treatment and monitoring to pharmaceutical and food processing. Meter comes in both Galvanic and Amperometric versions.

  • Readings values in mg/L or % air saturations, selectable from menu options
  • Quick, easy calibration using atmospheric air as calibration media for 100 % air saturation
  • Pressure, Salinity and Automatic Temperature Compensation

The Galvanic Electrode (ECDOGEN-S & ECDOTPII-S):

Rugged and long-lasting, the galvanic electrode requires no warm-up time and prevents zero drift by recreating H2O within the electrode. This prevents change of pH to the electrode and allows it to recycle within the probe. The result: galvanic sensors have long lifespans and require low maintenance costs.

The Amperometric Electrode (EC237150 & EC237450)

The amperometric dissolved oxygen electrode contains special membranes that are designed to require almost zero maintenance. These unique membranes stay stable even under harsh ambient conditions and high pressure. This enables the sensors to capture accurate DO readings within short response time at required flow as low as 0.02 m/s.

Applications

General: Useful for monitoring temperature and control of DO in wastewater treatment and aquaculture applications. Use with valves, blowers or aerators to ensure proper system operation.

Order Information

TSDOCTP2000W: Alpha DO 2000 galvanic wall-mount Dissolved Oxygen controller/transmitter. Incl. terminal blocks, cable glands, gasket, etc

TSDOCTP2000WPG: Alpha DO 2000 polarographic wall-mount Dissolved Oxygen controller/transmitter. Incl. terminal blocks, cable glands, gasket, etc

TSDOCTP2000PPG: Alpha DO 2000 polarographic panel-mount Dissolved Oxygen controller/transmitter. Incl. terminal blocks, gasket, threaded rods, catch, etc.


For more information, please contact us
Exclusive representative of Eutech – Thermo Scientific in Vietnam

Specification

Dissolved Oxygen
  • Range: 
    • 0.00 to 25.00 mg/L or ppm; 0.0 to 300.0 % (For TSDOCTP2000W)
    • 0.00 to 20.00 mg/L or ppm; 0.0 to 200.0 % (For TSDOCTP2000WPG & TSDOCTP2000PPG)
  • Resolution: 0.01 mg/L or ppm; 0.1 %
  • Accuracy: 
    • ±1.5 % of full scale reading (For TSDOCTP2000W)
    • ±1 % of full scale reading (For TSDOCTP2000WPG & TSDOCTP2000PPG)
Temperature
  • Range: -10.0 to 125.0 ºC / 14.0 to 257.0 ºF
  • Resolution: 0.1 ºC / 0.1 ºF
  • Accuracy: ±0.5 ºC / ±1.0 ºF
  • Sensor:
    • Pt 100/Pt 1000 (jumper selectable); 2 or 3 wire (For TSDOCTP2000W)
    • NTC 22 kOhm thermistor (For TSDOCTP2000WPG & TSDOCTP2000PPG)
Set Point And Controller Functions
  • Set Point 1 (SP1) / Set Point 2 (SP2):
    • 0.00 to 25.00 mg/L or ppm; 0.0 to 300.0 % (For TSDOCTP2000W)
    • 0.00 to 20.00 mg/L or ppm; 0.0 to 200.0 % (For TSDOCTP2000WPG & TSDOCTP2000PPG)
  • Switching DO Hysteresis:
    • 0 to 10.0 % (For TSDOCTP2000W)
    • 1.0 to 10.0 %(For TSDOCTP2000WPG & TSDOCTP2000PPG)
  • Function (Switchable): P/PI control (pulse length/pulse frequency/proportional integral); limit control; off
  • Adjustable Period With Pulse Length Controller: 0.5 to 20 sec
  • Adjustable Period With Pulse Frequency Controller: 60 to 120 pulse/min
  • Integral Action Time (IAT): 0.0 to 999.9 min
  • Pickup/Dropout Delay: 0 to 2000 sec
  • Wash Cycle: 0.1 to 200.0 hr
  • Wash Duration: 1 to 2000 sec
  • Contact Outputs: 1 SPDT, 3 SPST relays
  • Switching Voltage/ Current/Power: (For TSDOCTP2000W)
    • 1/8 HP: at 125 VAC / max. 0.74 A / max. 93 VA
    • 1/8 HP: at 250 VAC / max. 0.37 A / max. 93 VA
  • Switching Voltage/ Current/Power (For TSDOCTP2000WPG & TSDOCTP2000PPG): Max. 250 VAC / max. 3 A / max. 600 VA 
 