CONDUCTIVITY CONTROLLER-TRANSMITTER ALPHA COND 2000
THERMO SCIENTIFIC – USA
General introduction:
Measure from ultra-pure water to highly conductive samples with the Conductivity controller-transmitter Alpha COND 2000 of Eutech – Thermo Scientific: this conductivity controller accepts 4-cell and 2-cell electrodes, and features programmable temperature coefficients to give you precise temperature compensation.

Conductivity controller/transmitter Alpha COND 2000
Features of Conductivity controller-transmitter Alpha COND 2000:
- Measures seven ranges, from 0 to 2 µS/cm to 0 to 1000 mS/cm.
- Readings of up to three-decimal resolution at ±1 % accuracy.
- Adjustable temperature coefficients for more precise temperature compensation: Choose between programmable linear temperature compensation from 0.0 % to 10.0 %, and pure water temperature compensation to correct
non-linearity of ultrapure water temperature correction curves.
- Meter displays electrode status after each calibration
- User-adjustable cell constant values (k = 0.005 to k = 9.999).
- 4-cell electrode prevents polarizing effects and
electrode fouling in samples with high conductivity.
- Accepts 2- or 3-wire, Pt100 or Pt1000 RTD sensors for automatic temperature compensation.
- Allows user to input cell constant corresponding to connecting electrode independently during calibration.
Applications
Conductivity controller-transmitter Alpha COND 2000 is used in:
General: Use for virtually any batch or online applications where rapid, accurate control. Great for OEM/system integrator.
Industrial: Use in applications involving agriculture, chemical processing, boiler and water heaters, wafer-fab, microprocessor manufacturing, pharmaceuticals, pulp and paper industries, and bleach manufacturing.
Water Purification/Treatment: Use to treat batches of incoming process water, ultrapure water, boiler and feed water control.
Regulatory: Hook to recorder to document data for regulatory compliance.
Order No.
TSCONCTP2000W: Alpha COND 2000 wall-mount Conductivity controller transmitter. Incl. terminal blocks, cable glands, gasket, etc
TSCONCTP2000P: Alpha COND 2000 panel-mount Conductivity controller transmitter. Incl. terminal blocks, gasket, threaded rods, catch, etc
Conductivity:
- Range ...to 2.000 µS/cm ; ...to 20.00 µS/cm ;
...to 200.0 µS/cm ; ...to 2000 µS/cm ;
...to 20.00 mS/cm ; ...to 200.0 mS/cm
...to 1000 mS/cm
- Resolution 0.001 µS/cm ; 0.01 µS/cm ;
0.1 µS/cm ; 1 µS/cm ;
0.01 mS/cm ; 0.1 mS/cm ;
1 mS/cm
Accuracy ±1 % of full scale reading (±2 % >500 mS/cm)
Temperature:
- Range -10.0 to 125.0 ºC (14.0 to 257.0 ºF)
- Resolution 0.1 ºC / 0.1 ºF
- Accuracy ±0.5 ºC / ±1.0 ºF
- Sensor Pt100/Pt1000 (jumper selectable); 2 or 3 wire
- Compensation Auto/manual (normalized at 25 ºC)
Set Point And Controller Functions:
- Set Point 1 (SP1) / Set Point 2 (SP2):
- ... to 2.000 µS/cm or ... to 20.00 µS/cm or
- ... to 200.0 µS/cm or ... to 2000 µS/cm or
- ... to 20.00 mS/cm or ... to 200.0 mS/cm or
- ... to 1000 mS/cm
- Switching Conductivity Hysteresis: 0 to 10 % of full scale
- Function (Switchable): P/PI control (pulse length/pulse frequency/proportional integral); limit control; off
- Adjustable Period With Pulse Length Controller: 0.5 to 20 sec
- Adjustable Period With Pulse Frequency Controller: 60 to 120 pulse/min
- Integral Action Time (IAT):0 to 999.9 min
- Pickup/Dropout Delay: 0 to 2000 sec
- Wash Cycle: 0.1 to 200.0 hr
- Wash Duration: 1 to 2000 sec
- Contact Outputs: 1 SPDT, 3 SPST relays
- Switching Voltage/ Current/Power:
- 1/8 HP: at 125 VAC / max. 0.74 A / max. 93 VA
- 1/8 HP: at 250 VAC / max. 0.37 A / max. 93 VA
Alarm Functions
- Function (Switchable): Steady or fleet (pulse)
- Pickup Delay: 0 to 2000 sec
- Switching Voltage/Current/Power
- 1/8 HP: at 125 VAC / max. 0.74 A / max. 93 VA
- 1/8 HP: at 250 VAC / max. 0.37 A / max. 93 VA
Electrical Data & Connections:
- Transmitter Function: Two 0/4 to 20 mA scalable outputs for Conductivity and temperature, galvanically isolated
- CU 22 Function: 22 mA current output
- Isolated Output Voltage: 12 V ±0.5 V (max. 50 mA)
- Hold Function Switch: To freeze output current and deactivate control relays
- Load: Max. 600 Ohm
- Conductivity Input: 2-cell/4-cell terminal
- Connection Terminal:
- 5-pin, 8-pin, 9-pin,13-pin terminal detachable blocks(For TSCONCTP2000W)
- 5-pin, 9-pin & 19-pin terminal, detachable blocks(For TSCONCTP2000P)
- Display: LCD UV coat, backlit 14 segments display with symbols for status information
- Backlight: On/off selectable with four level of brightness control
Power Supply
- Input: 80 to 250 VAC/DC ; 50/60 Hz ; 10 VA
- Main Fuse: 315 mA, anti-surge, 250 V
- Pollution Degree: 2
- Transient Overvoltage Category: II